Considerations for imaging thick, low contrast, and beam sensitive samples with liquid cell transmission electron
Trevor H Moser1, Tolou Shokuhfar2, James E Evans3
1Environmental Molecular Sciences Laboratory, 3335 Innovation Blvd., Richland, WA 99354, USA; Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931, USA.
Abstract:
Transmission electron microscopy of whole cells is hindered by the inherently large thickness and low atomic contrast intrinsic of cellular material. Liquid cell transmission electron microscopy allows samples to remain in their native hydrated state and may permit visualizing cellular dynamics in-situ. However, imaging biological cells with this approach remains challenging and identifying an optimal imaging regime using empirical data would help foster new advancements in the field. Recent questions about the role of the electron beam inducing morphological changes or damaging cellular structure and function necessitates further investigation of electron beam-cell interactions, but such comparisons are complicated by variability in imaging techniques used across various studies currently present in literature. The necessity for using low electron fluxes while imaging biological samples requires finding an imaging strategy which produces the strongest contrast and signal to noise ratio for the electron flux used. Here, we experimentally measure and evaluate signal to noise ratios and damage mechanisms between liquid and cryogenic samples of intact cells using multiple electron imaging modalities all on the same instrument and with equivalent beam parameters to standardize the comparison. We also discuss considerations for optimal electron microscopy imaging conditions for future studies on whole cells within liquid environments.
Related Concept Videos
Transmission Electron Microscopy
Transmission Line Design Considerations
Preparation of Samples for Electron Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Overview of Electron Microscopy