Related Experiment Video
Updated: Feb 2, 2026

10:44
An Introduction to Worm Lab: from Culturing Worms to Mutagenesis
Published on: January 11, 2011
35.7K
The Pollard lab at Salk: moving the leading edge forward
1Department of Biochemistry and Cell Biology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA. henry.n.higgs@dartmouth.edu.
Biophysical Reviews
|November 14, 2018
Summary
The Pollard lab
Area of Science:
- Molecular biology
- Cell biology
- Biochemistry
Background:
- The Pollard lab was established at the Salk Institute in the latter half of the 1990s.
- This period was characterized by significant scientific advancements and a focus on training.
- The lab's work during this time has had a lasting impact on the principal investigator's career trajectory.
Purpose of the Study:
- To provide a retrospective review of the Pollard lab's research activities and training environment at the Salk Institute during the late 1990s.
- To highlight the productivity and impact of the lab during this specific period.
- To reflect on the long-term personal and professional development influenced by this experience.
Main Methods:
- Literature review of publications and research output from the Pollard lab (late 1990s).
- Analysis of training records and contributions to the scientific community.
- Personal reflection and anecdotal evidence regarding career development.
Main Results:
- The Pollard lab experienced a highly productive period of research and training.
- The lab's activities contributed significantly to the fields of molecular and cell biology.
- The experience profoundly shaped the principal investigator's scientific career.
Conclusions:
- The Pollard lab's tenure at the Salk Institute in the late 1990s was a pivotal and highly productive phase.
- The lab fostered an environment conducive to both groundbreaking research and effective scientific training.
- The impact of this period continues to influence the principal investigator's ongoing scientific endeavors and career path.
Related Concept Videos
Flame Photometry: Lab
951
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
951
Phase-lead and Phase-lag Controllers
550
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
550
Atomic Absorption Spectroscopy: Lab
1.1K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.1K
Atomic Emission Spectroscopy: Lab
634
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
634
Magnetic Field due to Moving Charges
11.6K
A stationary charge creates and interacts with the electric field, while a moving charge creates a magnetic field.
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
11.6K
Time and frequency -Domain Interpretation of Phase-lead Control
454
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
454

