Related Experiment Video
Updated: Feb 2, 2026

Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Impairments in Postural Control and Retest Reliability of Dynamic Posturographic Measures After Lung Transplantation
Gerold Ebenbichler1, Stephan Doblhammer, Melanie Pachner
1From the Department of Physical Medicine, Rehabilitation and Occupational Medicine, Vienna Medical University, Vienna, Austria (GE, SD, MP); Karl Landsteiner Institute of Outpatient Rehabilitation Research, Vienna, Austria (RH, TK); Department of Psychology, Harvard University, Cambridge, Massachusetts (PM); Department of Sports Kinanthropology, Faculty of Physical Education and Sport, Comenius University in Bratislava, Slovakia (EZ); Institute of Normal and Pathological Physiology, Centre of Experimental Medicine, Slovak Academy of Sciences, Bratislava, Slovakia (ZH); and Department of Thoracic Surgery, Vienna Medical University, Vienna, Austria (PJ, WK).
Objectives:
The aims of the study were to classify impairments in postural control using computerized posturography in lung transplant recipients undergoing subacute rehabilitation and to examine the retest reliability of these measures.
Methods:
In a prospective repeated-measures study, 50 lung transplant recipients underwent clinical and quantitative posturographic testing (SMART EquiTest), which included the sensory organization test, motor control test, and limits of stability test. Testing was repeated after 1 to 2 days and upon completion of rehabilitation, 2 mos later. Main outcome measures were the following: sensory organization test-composite score, motor control test-latency and amplitude scaling, limits of stability test-movement velocity, and endpoint excursion/maximum excursion.
Results:
At the beginning of rehabilitation, the mean sensory organization test-composite score and limits of stability test, but not the motor control test scores, were below normative reference values and and did not return to normal after rehabilitation. Intraclass correlation coefficients(2,1) yielded excellent relative reliability for all posturographic tests. The smallest detectable differences observed for the sensory organization test and limits of stability test exceeded the mean changes observed upon completion of rehabilitation.
Conclusions:
Impairments in sensory and anticipatory postural control were insufficiently restored after subacute lung transplantation rehabilitation. The little sensitivity of the sensory organization test-composite score or limits of stability test scores to detect a minimal change in performance due to rehabilitation limits the clinical applicability of these tests as objective outcome measures in lung transplantation rehabilitation.
Related Concept Videos
Reliability and Validity
Lung Capacity
Distribution Reliability and Automation
Dynamic Equilibrium
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...