Does low-frequency vibration have an effect on aligner treatment? A single-centre, randomized controlled trial
Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Luca Lombardo1, Angela Arreghini1, Luis T Huanca Ghislanzoni2
1Postgraduate School of Orthodontics, University of Ferrara, Italy.
Background:
Low-frequency vibrations have been proposed as a means of accelerating tooth movement and reducing orthodontic treatment times.
Objective:
To determine any differences in the accuracy of dental movement in patients treated with a low-frequency vibration aligner protocol and/or by reducing the aligner replacement interval with respect to a conventional protocol.
Design:
This trial was designed as a single-centre, randomized controlled clinical trial.
Methods:
Participants: Patients (aged 27.1 ± 9.0 years) who required orthodontic treatment with aligners. Randomization: Patients were randomly allocated to three arms as determined by a computer-randomization scheme. Group A were assigned a conventional protocol (aligners replaced every 14 days); group B also used a low-frequency vibration device for 20 minutes per day; group C followed the same vibration protocol but replaced their aligners every 7 days. Blinding: The operator who performed the set-up and the one who analysed the data were blinded to the group of the patients. Outcome: Pre- and post-treatment digital models were analysed using VAM software to identify the accuracy/imprecision of dental movements. One-way analysis of variance (P < 0.05) and the Bonferroni post hoc test were used to identify any statistically significant differences between the three arms in terms of the accuracy of tooth movement versus the prescription.
Results:
Numbers analysed: A total of 45 patients (15 for group) were analysed (i.e. 2286 dental movements). Outcome: No statistically significant differences emerged between groups A and C in the upper arch, or among groups A, B, and C in the lower. Group B displayed significantly greater accuracy with respect to group A in upper incisor rotation (P = 0.016), and to group C in vestibulolingual (P = 0.007) and mesiodistal tipping (P = 0.029) of the upper canines, and vestibulolingual tipping of the upper molars (P = 0.0001). Harms: No adverse events or side-effects were registered.
Conclusions:
Considering all tooth and movement types of the 45 participants, the mean total imprecision was 2.1 ± 0.9 degrees, with respect to a mean prescription of 5.7 ± 2.2 degrees. There was no difference in accuracy between replacing the aligners accompanied by low-frequency vibration every 7 days and replacing them every 14 days without vibration. Moreover, low-frequency vibration seemed to improve the accuracy of a conventional protocol in terms of upper incisor rotation.
Trial Registration:
The German Clinical Trials Register (DRK00015613).
Related Concept Videos
Load-frequency control
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Vibrating Concrete