[The effects of different activators on the release curve of human platelet-rich plasma]

Y W Zhuang1, Y M Zeng, Y F Chen

  • 1Department of Pulmonary and Critical Care Medicine, Second Affiliated Hospital of Fujian Medical University, Respiratory Medicine Center of Fujian province, Quanzhou 362000, China.

Objective: To compare and analyze the effects of different activators on the release curve of TGF-β(1) and PDGF-AB in platelet rich plasma(PRP). Methods: A total of 36 ml peripheral venous blood was obtained from 10 healthy adult volunteers, and the PRP was made by secondary centrifugation. The platelet activator was made by bovine thrombin 1 000 U in 1 ml 10% calcium chloride solution. The Thrombin-PRP group was made by PRP and the activator in a ratio of 10∶1.The Calcium chloride-PRP group was made in a ratio of 10∶1 by PRP and 10% calcium chloride solution instead. The fresh whole blood(whole blood group) and inactived PRP(PRP group) were used as the control groups. The 4 groups were incubated in warm water of 37 ℃ for 0, 1, 8, 24,72 and 168 h. A quantitative sandwich enzyme-linked immunosorbent assays(ELISA) was used to examine the amount of TGF-β(1) and PDGF-AB in different time points of each group. The release curves of TGF-β(1) and PDGF-AB were based on afore-mentioned data, and then comparisons of the release curves of TGF-β(1) and PDGF-AB in different groups were performed by repeated measurement variance analysis. Results: (1)The levels of TGF-β(1) and PDGF-AB in the whole blood group and the PRP group continued to increase within 168 h. PRP immediately formed into a gel after mixture with thrombin combined and calcium chloride, and the concentrations of TGF-β(1) and PDGF-AB reached the peak in 1 h after activation; increased from (42±21)ng/ml and (77±18)ng/ml to (84±21)ng/ml and (124±35)ng/ml, respectively, and then decreased gradually. The release curve was direct and rapid. The PRP became a gel state in approximate 1 h after mixture with calcium chloride, and the concentrations of TGF-β(1) and PDGF-AB were slowly rising and remained high at 168 h. (2)The AUC(0-168h) of TGF-β(1) and PDGF-AB in the PRP group was higher than that in the whole blood group (all P<0.05) , and the AUC(0-168h) of TGF-β(1) in the Calcium chloride-PRP group was higher than that in the Thrombin-PRP group(Z=-2.26, P<0.05).However, there was no significant difference in the AUC(0-168h) of PDGF-AB between the Calcium chloride-PRP group and the Thrombin-PRP group(Z=-1.512, P=0.131). Conclusion: Using calcium chloride as activator can get a higher release concentration of TGF-β(1) and PDGF-AB and a longer release time, with the largest area under the curve.

Related Concept Videos

Heating and Cooling Curves02:44

Heating and Cooling Curves

When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
27.8K
Activation Energy01:26

Activation Energy

Activation energy is the minimum amount of energy necessary for a chemical reaction to move forward. The higher the activation energy, the slower the rate of the reaction. However, adding heat to the reaction will increase the rate, since it causes molecules to move faster and increase the likelihood that molecules will collide. The collision and breaking of bonds represents the uphill phase of a reaction and generates the transition state. The transition state is an unstable high-energy state...
86.6K
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...
141.2K
z Scores and Area Under the Curve01:17

z Scores and Area Under the Curve

z scores are the standardized values obtained after converting a normal distribution into a standard normal distribution. A z score is measured in units of the standard deviation. The z score tells you how many standard deviations the value x is above (to the right of) or below (to the left of) the mean, μ. Values of x that are larger than the mean have positive z scores, and values of x that are smaller than the mean have negative z scores. If x equals the mean, then x has a z score of...
19.6K
Survival Curves01:18

Survival Curves

Survival curves are graphical representations that depict the survival experience of a population over time, offering an intuitive way to track the proportion of individuals who remain event-free at each time point. These curves are widely used in fields such as medicine, public health, and reliability engineering to visualize and compare survival probabilities across different groups or conditions.
The Kaplan-Meier estimator is the most common method for constructing survival curves. This...
718
Curve Equations01:17

Curve Equations

Curves are essential geometric elements characterized by tangent distance, chord length, middle ordinate, and total arc length. These measurements are crucial in understanding a curve's geometric and spatial properties and are defined by the relationship between its radius and its central angle.The tangent distance (T) refers to the straight-line measurement from the intersection point of two tangents to either the start or end of the curve. This distance is influenced by the curve's radius (R)...
355