Related Experiment Video
Updated: Feb 2, 2026

Stretching Short Sequences of DNA with Constant Force Axial Optical Tweezers
Published on: October 13, 2011
New Detector Sensitivity Calibration and the Calculation of the Interaction Force between Particles Using an Optical
Pavel Yale1, Jean-Michel Edoukoua Konin2, Michel Abaka Kouacou3
1Laboratoire d'Instrumentation, Image et Spectroscopie (L2IS), Institut National Polytechnique Houphouët-Boigny (INPHB), BP 1093 Yamoussoukro, Cote D'Ivoire. pavelyale@yahoo.fr.
Abstract:
We propose a new approach to calculate the sensitivity factor of the detector in optical tweezers. In this work, we used a charge-coupled device (CCD) camera and a quadrant photodiode (QPD) for the extraction of the various positions occupied by the trapped object (in this case, silica beads of different diameters). Image-J software and the Boltzmann statistical method were then used to estimate the sensitivity of the detector. Silica beads of diameter 0.8 µm, 2 µm, a system of 2 µm bead stuck to 4.5 µm one and another system of 2 µm beads stuck to 2 µm one, were studied. This work contributes significantly to making better calibration of the detector without taking into account the geometry of the object imprisoned in the optical trap. We further developed an approach to calculate the interaction force between two microbeads. This approach does not require any knowledge of solvent viscosity and works for all types of samples.
Related Concept Videos
Intermolecular Forces in Solutions
When the strengths of the intermolecular forces of attraction between solute and solvent species in a solution are no different than those present in the separated components, the solution is formed with no accompanying energy change. Such a solution is called an ideal solution. A mixture of ideal gases (or gases such as helium and argon,...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Intermolecular Forces
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
Intermolecular vs Intramolecular Forces