Microfluidic Analyzer Enabling Quantitative Measurements of Specific Intracellular Proteins at the Single-Cell Level
Lixing Liu1,2, Beiyuan Fan3,4, Diancan Wang5
1State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China. liulixing16@mails.ucas.ac.cn.
Abstract:
This paper presents a microfluidic instrument capable of quantifying single-cell specific intracellular proteins, which are composed of three functioning modules and two software platforms. Under the control of a LabVIEW platform, a pressure module flushed cells stained with fluorescent antibodies through a microfluidic module with fluorescent intensities quantified by a fluorescent module and translated into the numbers of specific intracellular proteins at the single-cell level using a MATLAB platform. Detection ranges and resolutions of the analyzer were characterized as 896.78⁻6.78 × 10⁵ and 334.60 nM for Alexa 488, 314.60⁻2.11 × 10⁵ and 153.98 nM for FITC, and 77.03⁻5.24 × 10⁴ and 37.17 nM for FITC-labelled anti-beta-actin antibodies. As a demonstration, the numbers of single-cell beta-actins of two paired oral tumor cell types and two oral patient samples were quantified as: 1.12 ± 0.77 × 10⁶/cell (salivary adenoid cystic carcinoma parental cell line (SACC-83), n = 13,689) vs. 0.90 ± 0.58 × 10⁵/cell (salivary adenoid cystic carcinoma lung metastasis cell line (SACC-LM), n = 15,341); 0.89 ± 0.69 × 10⁶/cell (oral carcinoma cell line (CAL 27), n = 7357) vs. 0.93 ± 0.69 × 10⁶/cell (oral carcinoma lymphatic metastasis cell line (CAL 27-LN2), n = 6276); and 0.86 ± 0.52 × 10⁶/cell (patient I) vs. 0.85 ± 0.58 × 10⁶/cell (patient II). These results (1) validated the developed analyzer with a throughput of 10 cells/s and a processing capability of ~10,000 cells for each cell type, and (2) revealed that as an internal control in cell analysis, the expressions of beta-actins remained stable in oral tumors with different malignant levels.
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Cell Specific Gene Expression
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...
Intracellular Signaling Cascades