Related Experiment Video
Updated: Feb 2, 2026

Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound
Published on: December 2, 2014
Off-Pump Plicating Ascending Aortoplasty With External Wrapping: Magnum in Parvo
Mladen J Kocica1, Milica M Karadzic1, Dragan D Cvetkovic1
1UC Clinical Centre of Serbia, Clinic for Cardiac Surgery, Belgrade, Serbia.
Background:
Isolated, fusiform aneurysms, exclusively affecting the tubular portion of the ascending aorta, are rare. Surgical treatment aims to change their natural course, reducing individual and cumulative risks of rupture, dissection and death. Open tubular graft replacement still remains the procedure of choice, despite significant risks. In permanent pursuit for optimal, alternative surgical strategy in high-risk patients, less invasive and off-pump plicating ascending aortoplasty with modified external Dacron graft wrapping seems to be a reliable choice.
Methods:
Two (2) consecutive patients were operated on. The same preoperative calculations and slightly different operative techniques were applied regarding surgical exposure and wrapping graft orientation. Immediate and late follow-up (5 years) results were compared.
Results:
Absolute and indexed target ascending aortic diameters remained acceptable (<2.1cm/m2 considered the upper normal range for adults). There were no significant changes in proximal and distal aortic diameters. Ascending aortic silhouette on contrast enhanced multi-detector CT was better with Dacron wrapping graft tailored to have its grooves in the longitudinal direction. Upper mini-sternotomy was quite appropriate for this procedure, from a surgical point of view, and was safe for the patient.
Conclusions:
Careful patient selection and using the current model of preoperative calculations and surgical technique resulted in acceptable and stable ascending aortoplasty in high-risk patients 5 years after surgery.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Internal and External Forces

