Related Experiment Video
Updated: Feb 2, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Visualization of the pulp chamber roof and residual dentin thickness by spectral-domain optical coherence tomography
Felix Krause1, Conny Köhler2, Claudia Rüger2
1Department of Cariology, Endodontology and Periodontology, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany. felix.krause@medizin.uni-leipzig.de.
Abstract:
The aim of this study was to evaluate the ability of spectral-domain optical coherence tomography (SD-OCT) to display the roof of the pulp chamber and to estimate the residual dentin thickness (RDT) of the pulp complex. The roots of 20 extracted human molars were embedded in epoxy resin, and crowns were longitudinally sectioned in the mesial-distal direction, exposing the pulp chamber. The coronal part of the crown was removed up to an RDT to the pulp chamber roof of 2 mm. Samples were imaged by SD-OCT from coronal view and by light microscopy (LM) in the sagittal plane. Using a microtome, dentin was subsequently removed in four levels from the occlusal aspect in steps of 250 μm. At each level, RDT was documented and measured by both methods. The data were compared (Spearman's rho correlation coefficient, Wilcoxon signed-rank test). Using OCT, the roof of the pulp chamber was first displayed at a maximum RDT of 1.94 mm. The minimal RDT that could be imaged by OCT was 0.06 mm. Values from both methods were strongly correlated (r, 0.83-0.95; pi ≤ 0.05) and differed significantly for large RDTs (dentin levels 1, 2; pi < 0.05) but not for small RDTs (levels 3, 4; pi ≥ 0.226). The roof of the dental pulp chamber could be already visualized by SD-OCT with a RDT of 1.94 mm. Therefore, the method could be a useful diagnostic tool during the preparation of deep dentin cavities and might help to preserve the integrity of the pulp chamber.
More Related Videos
06:19In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
Published on: November 11, 2017
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Residual Stresses
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...
Residual Stresses in Circular Shafts
Residual Stresses in Bending
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...