Related Experiment Video
Updated: Feb 2, 2026

Percutaneous Contrast Echocardiography-guided Intramyocardial Injection and Cell Delivery in a Large Preclinical Model
Published on: January 21, 2018
Feasibility and safety of exclusive echocardiography-guided intravenous temporary pacemaker implantation
Aref El Nasasra1, Hilmi Alnsasra2, Doron Zahger2
1Department of Cardiology, Soroka University Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 151, 84101, Beer Sheva, Israel. arefsalam@hotmail.com.
Background:
The standard approach for urgent trans-venous temporary cardiac pacemaker (TVTP) implantation is fluoroscopy guidance. The delay in activation of the fluoroscopy-room and the transfer of unstable patients may be life-threatening. Echocardiography-guided TP implantation may increase the safety of the patients by obviating the need for in-hospital transfer. We examined the feasibility and safety of echocardiography-guided vs. fluoroscopy-guided TVTP implantation.
Methods:
From January 2015 to September 2017 data for consecutive patients who needed emergent TVTP implantation were retrospectively reviewed. Ultrasound-guided TVTP protocol that was introduced in our center in January 2015 involved ultrasound guidance for both central venous access and pacing lead positioning. Access sites included femoral, subclavian, or jugular veins. Electrodes were placed in the right ventricular apex by means of echocardiographic monitoring in intensive care unit or by fluoroscopic guidance. Endpoints were achievement of successful ventricular pacing and procedural complications.
Results:
Sixty-six patients (17 echocardiography-guided and 49 fluoroscopy-guided) were included. There were no differences in pacing threshold between the echocardiography-guided group and the fluoroscopy-guided group (0.75 ± 0.58 mA vs. 0.57 ± 0.35 mA, p = 0.24). The access site for implantation was femoral vein in 27% for the fluoroscopy-guided vs. none for the echocardiography-guided approach (p = 0.015). One hematoma and one related infection occurred in the fluoroscopy-guided group. The need for electrode repositioning was observed in 1 patient in each group. There were no procedural-related deaths in either group.
Conclusions:
Echocardiography-guided temporary cardiac pacing is a feasible and safe alternative to fluoroscopy-guided approach and significantly lowers the need for in-hospital transfer.
More Related Videos
Related Concept Videos
The Pauli Exclusion Principle
Survey Safety
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Household Wiring And Electrical Safety
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography