Related Experiment Video
Updated: Feb 2, 2026

Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Retrospective analysis for valproate screening targets with liquid chromatography-high resolution mass spectrometry
Christian Brinch Mollerup1, Brian Schou Rasmussen1, Sys Stybe Johansen1
1Section of Forensic Chemistry, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Frederik V's vej 11, 2100, Copenhagen Ø, Denmark.
Abstract:
Liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) is an important analytical tool in the systematic toxicological analysis performed in forensic toxicology. However, some important compounds, such as the antiepileptic drug valproate (valproic acid; VPA), cannot be directly detected with positive electrospray ionization (ESI+ ) due to poor ionization. Here we demonstrate an omics-based retrospective analysis for the identification of indirect screening targets for VPA in whole blood with LC-ESI+ -HRMS. Analysis was performed utilizing data acquired across four years from LC-ESI+ -HRMS, with VPA results from a quantitative LC-MS/MS method. The combined data with VPA results were split into an exploration set (n = 68; 28% positive) and a test set (n = 37; 32% positive). Eight indirect targets for VPA were identified in the exploration set. The evaluation of these targets was confirmed with retrospective target analysis of the test set. Using a combination of two out of the eight indirect targets, we attained a sensitivity of 92% (n = 12; VPA concentration range: 4.4-29.7 mg/kg) and 100% specificity (n = 25) for VPA with LC-ESI+ -HRMS. VPA screening targets were identified with retrospective data analysis and could be appended to the existing screening procedure. A sensitive and specific screening with LC-ESI+ -HRMS was achieved with targets corresponding to the sodium adducts of C7 H14 O3 and C8 H14 O3 . Three chromatographic resolved isomer peaks were observed for the latter, and the consistently most intense peak was tentatively identified as 3-hydroxy-4-en-VPA.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: