Paclitaxel with or without trametinib or pazopanib in advanced wild-type BRAF melanoma (PACMEL): a multicentre,

V Urbonas1, D Schadendorf2, L Zimmer2

  • 1Early Phase Clinical Trials Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, UK; National Cancer Institute, Vilnius, Lithuania.

Abstract

Related Concept Videos

Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
550
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches01:23

Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches

Biopharmaceutical studies constitute a vital field aiming to enhance drug delivery methods and refine therapeutic approaches, drawing upon diverse interdisciplinary knowledge. In research methodologies, the choice between controlled and non-controlled studies significantly influences the study's reliability and accuracy.
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
471
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
2.4K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
454
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
420
Clinical Trials: Overview01:11

Clinical Trials: Overview

Clinical development focuses on how the drug will interact with the human body and encompasses four key phases of clinical trials, each serving a specific purpose in assessing the safety and effectiveness of new drugs. These phases overlap and build upon one another. Phase I involves a small group of healthy volunteers (typically 20-80 individuals) or, in cases where significant toxicity is expected, patients with the targeted disease, such as cancer or AIDS. The volunteers are tested for...
5.0K