Related Experiment Video
Updated: Feb 2, 2026

Simulating Imaging of Large Scale Radio Arrays on the Lunar Surface
Published on: July 30, 2020
Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array
Hui Chen1, Mu Gu2, Xiaolin Liu1
1Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai, 200092, P. R. China.
Abstract:
The performances of the pixelated CsI(Tl) scintillation screens based on oxidized silicon micro-pore array templates with different CsI(Tl) micro-column shapes and array structures in X-ray imaging were simulated using the Geant4 Monte Carlo simulation code. The shapes of the micro-columns include square, hexagonal and circular, and the array structures include square and hexagonal arrangements. The pitch size of the pixelated CsI(Tl) scintillation screens was set to 4 µm, and the incident X-ray energy was set to 20 keV. The ratios of the number of scintillation photons that propagate along the CsI(Tl) micro-columns to the total number of scintillation photons of the micro-columns gradually decrease with the increase in total reflection time on the lateral surfaces of the micro-columns. However, these ratios are closely related to the shapes of the micro-columns and the incident positions of X-ray on the cross-sections of the micro-columns, especially for the circular micro-column. The sequence of bottom light outputs stimulated by a uniform flood field of X-ray from high to low corresponds to the circular, square and hexagonal CsI(Tl) micro-columns with the same cross-section areas. In addition, all spatial resolutions in terms of modulation transfer functions (MTFs) for the pixelated CsI(Tl) scintillation screens with square and hexagonal array structures are over 100 lp/mm. However, the resolution for the pixelated screen with the hexagonal array structure is approximately 8.5% higher than that for the screen with the square array structure. Moreover, the former screen has a higher detective quantum efficiency (DQE) than the latter screen at the same thickness. The pixelated CsI(Tl) scintillation screen with circular micro-column and hexagonal array structure in X-ray imaging has superior performance compared to other pixelated screens in this work.
Related Concept Videos
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Molecular Shapes
Two regions of electron density in a diatomic...
VSEPR Theory and the Basic Shapes
Molecular Shape and Polarity

