Live-cell labeling of endogenous proteins with nanometer precision by transduced nanobodies

A Klein1, S Hank1, A Raulf2

  • 1Institute of Biochemistry, Biocenter , Goethe University Frankfurt , Max-von-Laue-Str. 9 , 60438 Frankfurt/Main , Germany .

Chemical Science
|November 16, 2018
PubMed

Related Concept Videos

Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.7K
Transducer Mechanism: G Protein–Coupled Receptors01:30

Transducer Mechanism: G Protein–Coupled Receptors

G Protein–Coupled Receptors (GPCRs) are membrane-bound receptors that transiently associate with heterotrimeric G proteins and induce an appropriate response to various stimuli. GPCRs regulate critical physiological pathways and are excellent drug targets for treating diseases such as diabetes, cancer, obesity, depression, or Alzheimer's. Nearly 35% of approved drugs implement their therapeutic effects by selectively interacting with specific GPCRs.
GPCRs are also called heptahelical,...
4.2K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
101.2K
Accuracy and Precision01:52

Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
15.3K
Transducer Mechanism: Nuclear Receptors01:31

Transducer Mechanism: Nuclear Receptors

Nuclear receptors, or NRs, are unique transcription factors that regulate gene transcription and affect the cellular pathways involved in reproduction, development, or metabolism. Their ability to be stimulated by small lipophilic ligands and control vital cellular processes makes them ideal drug targets. Nearly 10-15% of currently prescribed drugs target these receptors.
About 48 different soluble family members of nuclear receptors are identified that can be divided into two main classes:
2.5K
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic01:26

Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic

Healthcare-associated infections (HAIs) occur in a healthcare facility while a person receives care for another ailment. This category also includes work-related infections among healthcare staff.
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
5.5K