Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Advancing Biopsy Techniques with Transesophageal Ultrasound
Published on: November 21, 2023
Clinical and endoscopic response to high dose rate endobronchial brachytherapy in malignant lung tumors: A single
Sneha Dhillon1, Saurabh Bansal1, Girish Sindhwani2
1Department of Radiation Oncology, Cancer Research Institute, SRHU, Dehradun, Uttarakhand, India.
Purpose:
The aim of the study was to evaluate the short-term clinical, endoscopic response, and acute toxicities in endobronchial cancer treated with high-dose-rate endobronchial brachytherapy (HDR-EB).
Materials And Methods:
Thirty patients of advanced endobronchial cancers were treated with HDR-EB. Brachytherapy was delivered at a depth of 1 cm from the source axis at weeks 1, 2, and 3 with 7 Gy per fraction. All patients were evaluated before treatment and at 1 month after completion of therapy. Using Speiser's scoring criteria, the severity of symptoms (dyspnea, cough, hemoptysis, and postobstructive pneumonia) and degree of obstruction were graded.
Results:
Symptomatic response for cough, dyspnea, and hemoptysis was seen in 88%, 75%, and 96%, respectively, with a significant P value (<0.05). Obstructive pneumonia was resolved in 94% of patients. Endoscopic response in terms of degree of obstruction was seen in 84% of patients. Acute toxicities in the form of radiation bronchitis were seen in 32% of patients, whereas 8% of patients experienced esophagitis. Bronchospasm was seen in one patient during treatment.
Conclusion:
HDR brachytherapy is a highly effective, safe, convenient therapy in alleviating symptoms of endobronchial obstruction with endoscopic response in the majority of cases. Thus, HDR-BT is a promising treatment for palliation of patients presenting with symptoms of endobronchial obstruction with an acceptable rate of complications.
More Related Videos
Related Concept Videos
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Dose-Response Relationship: Selectivity and Specificity
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Lung Capacity
Bioavailability Study Design: Single Versus Multiple Dose Studies