Feasibility of Noninvasive Blood Pressure Measurement using a Chest-worn Patch Sensor
Abstract:
Pulse arrival time (PAT) and pulse transit time (PTT) derived from the finger have been widely investigated for noninvasive blood pressure (BP) measurement. The study investigates the feasibility of BP measurement using a chestworn patch sensor derived systolic timing intervals and pulse timing measurements. Healthy volunteers (N=14, 38 ± 13 years) carried out a protocol including deep breathing test, sustained hand grip test and modified Valsalva test with continuous physiological measurements from a patch sensor attached on left chest and intermittent BP measurements from an automated oscillometric monitor as a reference. The efficacy of chest derived PAT and PTT for univariate BP prediction is assessed using correlation and regression slope. The cross validation performance of predicting BP using multivariate regression model with chest derived systolic timing intervals and pulse timing features were also evaluated. The results suggest that the chest derived PAT and PTT had modest correlations (-0.52 and -0.31) and regression slopes (-0.21 and -0.14) with automated oscillometric systolic and diastolic BP references, respectively. On the other hand, a multivariate regression approach for prediction of mean blood pressure (MBP) using patch sensor measurements showed a correlation of 0.72, mean error of 0.1 mmHg and RMSE error of 5.1 mmHg compared to the oscillometric MBP values. The study demonstrated the feasibility of BP measurement using a wearable chest-worn patch sensor in healthy control subjects.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...