Related Experiment Video
Updated: Feb 2, 2026

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
Published on: May 5, 2022
Real-time Evaluation of ECG Acquisition Systems through Signal Quality Assessment in Horses during Submaximal
Abstract:
This paper reports on a novel real time index designed to assess the quality of electrocardiographic (ECG) traces recorded in a group of five horses during a submaximal treadmill test procedure. During the experimental protocol two ECG monitoring systems were simultaneously applied to the animals. The first system was equipped with textile electrodes while the second one with standard red-dot electrodes. The procedure comprised four phases with an increased treadmill velocity, specifically, Walk 1, Trot 1, Trot 2 and Gallop. Three signal quality levels have been fixed according to the amount of noise present in the ECG trace: good (G), acceptable (A), and unacceptable (U). Moreover, a statistical comparison between textile and red-dot electrodes has been performed in terms of percentage of signal belonging to each class. Even if preliminary, results showed that in each experimental phase textile electrodes are more robust to movement artifacts with respect to the reddot showing a significant evidence of their better performance. These results enable to design robust wearable monitoring systems suitable to improve the quality of collected ECG, reducing the great amount of motion artifacts due to red-dot electrode application and leading to a more accurate diagnosis of high speed arrhythmias.
Related Concept Videos
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Basic Discrete Time Signals
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...
Sampling Continuous Time Signal
In the...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Actin Treadmilling

