Related Experiment Video
Updated: Feb 2, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Performance Assessment of a Dedicated Reflectance Pulse Oximeter in a Neonatal Intensive Care Unit
Abstract:
The measurement of peripheral oxygen saturation (SpO2) in neonatal intensive care units (NICUs) poses a significant challenge. Motion artifacts due to the patient's limb motion induce many false alarms, which in turn cause an additional workload for the medical staff and anxiety for the parents. We developed a reflectance pulse oximeter dedicated to be placed at the patient's forehead, which is less prone to such artifacts. We trained our algorithms for SpO2 estimation on 8 adult healthy volunteers participating in a controlled desaturation study. We then validated our SpO2 monitoring system on 25 newborn patients monitored in an NICU. We further evaluated the versatility and resilience to low signal-tonoise ratios (SNR) of our solution by testing it on signals acquired in a low-perfusion region (upper right part of the chest) of our adult volunteers. We obtained an SpO2 estimation accuracy ($A _{\mathbf {rms}}$) of 1.9 % and 3.1 % at the forehead and the chest in our adult volunteers, respectively. These performances were obtained after automatic rejection of 0.1 % and 30.0 %, respectively, of low-SNR signals by our dedicated quality index. In the dataset recorded on newborn patients in the NICU, we obtained an accuracy of 3.9 % after automatic rejection of 11.7 % of low-SNR signals by our quality index. These analyses were carried out following the procedures suggested by the ISO 80601-2-61:2011 standard, which specifies a target $A _{\mathbf {rms}} \le $ 4 % for SpO2 monitoring applications. These promising results suggest that reflectance pulse oximeters can achieve clinically acceptable accuracy, while being placed at locations less sensitive to limb motion artifacts - such as the forehead - thereby reducing the amount of SpO2-related false alarms in NICUs.
More Related Videos
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Measurement: Standard Units
Measurement: Derived Units

