Fully Disposable Wireless Patch Sensor for Continuous Remote Patient Monitoring
Summary
The VitalPatch biosensor offers accurate, continuous remote patient monitoring. This disposable wireless device effectively tracks vital signs and activity, aiding early detection of patient deterioration.
Area of Science:
- Biomedical Engineering
- Wearable Technology
- Remote Patient Monitoring
Background:
- Continuous remote monitoring is crucial for early detection of patient deterioration.
- Wireless biosensors offer a convenient solution for unobtrusive patient care.
- Existing solutions require validation for accuracy and reliability.
Purpose of the Study:
- To introduce the VitalPatch, a novel disposable wireless biosensor.
- To evaluate the performance of VitalPatch through bench testing and laboratory validation.
- To assess the clinical acceptability of VitalPatch for continuous patient monitoring.
Main Methods:
- Bench testing using ECG databases for QRS detection.
- Laboratory validation in 57 subjects measuring heart rate (HR), respiration rate (BR), and skin temperature.
- Actigraphy metrics including step detection, posture detection, and fall detection.
Main Results:
- VitalPatch demonstrated high accuracy in QRS detection (>99% positive predictive value).
- Bench testing showed low Mean Absolute Error (MAE) for HR (<5 bpm), BR (<1 brpm), and skin temp (<1°C).
- Laboratory testing confirmed accurate HR (2.2±1.5 bpm) and BR (1.7±0.7 brpm) measurements, with high accuracy in step (4.7±4.6%) and posture (96.4±3.1%) detection. Fall detection showed 100% sensitivity and 93.8% specificity.
Conclusions:
- The VitalPatch biosensor provides clinically acceptable accuracy for vital signs and actigraphy.
- This disposable wireless sensor is suitable for continuous, unobtrusive patient monitoring.
- VitalPatch supports early detection of patient deterioration and enhances patient care.
More Related Videos
Related Concept Videos
Long-patch Base Excision Repair
8.0K
Since the discovery of the two BER pathways, there has been a debate about how a cell chooses one pathway over the other and the factors determining this selection. Numerous in vitro experiments have pointed out multiple determinants for the sub-pathway selection. These are:
8.0K
Continuing Care
2.0K
Continuing care describes the variety of health, personal, and social services provided over a prolonged period. The need for continuing care is increasing because people are living longer. Many people do not have families or others to care for them. Continuing care is mainly for patients who are disabled, functionally dependent, or suffering from a terminal disease. It is available within institutional settings or in homes. Examples include nursing centers or facilities, assisted living,...
2.0K
Continuity of a Function
241
A function is continuous at a point a if three conditions are met: the function is defined at a, the limit of the function as x approaches a exists, and this limit equals the function’s value. Mathematically, this is written asThis definition ensures the graph of the function does not exhibit any breaks, holes, or jumps at that point. Discontinuities occur when any of these conditions fail. A removable discontinuity exists when the two-sided limit exists but the function is either...
241
Continuity Equation
3.3K
The continuity equation asserts that the mass flow rate must remain constant for a steady flow of an incompressible fluid within a confined system. This principle applies to systems where fluid passes through varying cross-sectional areas, such as nozzles, syringes, and pipes.
The mass flow rate is expressed as:
The mass flow rate is expressed as:
3.3K
Continuity Equation
1.5K
The total amount of current flowing per unit cross-sectional area is called the current density. Hence, the current passing through a cross-sectional area can be written as the surface integral of the current density.
1.5K
Equation of Continuity
11.1K
Fluid motion is represented by either velocity vectors or streamlines. The volume of a fluid flowing past a given location through an area during a period of time is called the flow rate Q, or more precisely, the volume flow rate. Flow rate and velocity are related—for instance, a river has a greater flow rate if the velocity of the water in it is greater. However, the flow rate also depends on the size and shape of the river. The relationship between flow rate (Q) and average speed (v)...
11.1K