Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Repetitive Transcranial Magnetic Stimulation Combined with Movement Observation in Cerebral Palsy
Published on: August 9, 2024
Repeatability of EMG activity during exoskeleton assisted walking in children with cerebral palsy: implications for
Abstract:
Effective solutions for gait rehabilitation in children with cerebral palsy (CP) remain elusive. Wearable robotic exoskeletons offer the potential to greatly increase the dosage and intensity of gait training in this population, which may improve outcomes. We recently reported that a robotic exoskeleton significantly improved knee extension in children with crouch gait from CP. Longitudinal studies are necessary to fully understand long term biomechanical effects of exoskeleton gait training. Given that children's gait can change both as they develop and throughout their therapy, advanced control strategies which can adapt assistance over time may be beneficial. But, stride-to-stride variability makes it difficult to ascertain the effects of exoskeleton assistance and therefore complicates implementation of adaptable control algorithms. Here, we examine the use of the variance ratio (VR), a previously published measure, to assess the effect of exoskeleton assistance on knee extensor and flexor EMG variability in children with CP. Our results show that VR was significantly increased ($p<0.001)$ compared to baseline during walking with exoskeleton assistance. After five practice sessions, we found that VR was reduced though still greater than baseline levels. Given its sensitivity to exoskeleton assistance and ease of computation, VR may be a useful measure in the future for evaluating stride-to-stride variability in real time to inform algorithmic decision making for autonomous adaptable control.
More Related Videos
08:26Event-related Potentials During Target-response Tasks to Study Cognitive Processes of Upper Limb Use in Children with Unilateral Cerebral Palsy
Published on: January 11, 2016
04:13Using a Real-Time Locating System to Measure Walking Activity Associated with Wandering Behaviors Among Institutionalized Older Adults
Published on: February 8, 2019
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Drug Dosing: Infants and Children