Related Experiment Video
Updated: Feb 2, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Capacitive Micromachined Ultrasonic Transducer (CMUT)-based Biosensor for Detection of Low Concentration Neuropeptide
Abstract:
Accurate detection of neuropeptides in cerebrospinal fluid (CSF) plays an important role in both indepth studies and early diagnosis of neurological diseases. Here, we report a biosensor based on Capacitive Micromachined Ultrasonic Transducer (CMUT) which is capable of detecting low concentrations (pg $\sim $ ng/ml) of a neuropeptide involved with the progression of Alzheimer's diseases, somatostatin (SST). A 10-MHz CMUT was fabricated and utilized as a physical resonant sensor which detects the change in the concentration of analyte through the mass-loading mechanism. The resonant plate was sequentially coated with protein G and antibodies to provide specificity to SST; Cysteine-tagged protein G layer enables controlled immobilization of antibodies in a welloriented manner. The change in the resonant frequency of the CMUT sensor was measured after incubating the sensor in various concentrations of SST. The significant shifts in the resonant frequency were observed for SST concentrations in the range of 10 pg/ml $\sim 1$ ng/ml. Compared to the previously reported biosensors developed for SST detection, our sensor shows discernable responses for SST that are $\sim 6$ orders of magnitude lower in concentration. Thus, this work demonstrates the potential of the CMUT resonant sensor as a promising biosensor platform for detection of neuropeptides involved with neurodegenerative diseases that often exist in low concentrations in CSF.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
08:20Time-Resolved In Vivo Measurement of Neuropeptide Dynamics by Capacitive Immunoprobe in Porcine Heart
Published on: May 19, 2022
Related Concept Videos
Equivalent Capacitance
Equivalent Capacitance
The following strategies are adopted to calculate...
Capacitors and Capacitance
When the conductors are two identical parallel plates, it is called a parallel plate capacitor. When battery terminals are...
Concentration Cells
Consider the following voltaic cell:
Design Example: Capacitance Multiplier Circuit
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...