Brain Mapping Using a Graphene Electrode Array
Published on: October 20, 2023
Performance of graphene ECG electrodes under varying conditions
Abstract:
Smart garments for invisible health sensing have been available for a number of years, with heart sensing typically performed using silver loaded conductive threads integrated into the fabric to pick up the electrocardiogram. Recent work has investigated printed graphene textiles as an alternative to this, which are potentially more environmentally friendly, cost-effective, and can be performed after garment manufacturing. This paper presents an exploration of second order factors on the performance of graphene textile electrodes for electrocardiogram measurements. We prepare graphenebased textile electrodes using a simple and highly scalable continuous padding method. We then analyze two metrics: the change in heart rate estimation error, and the changes in signal-to-noise ratio; under two separate conditions: an extended record length, and varying temperatures; to recreate the some of the conditions the material would experience when being worn in real-life. We report that neither the heart rate estimation error or the signal-to-noise ratio are significantly affected after a long record or with varying temperature. These tests indicate that graphene electrodes are suitable for electrocardiogram measurements in a wearable that will be subjected to these conditions.
Related Concept Videos
Standard Electrode Potentials
Gradually Varying Flow
Rapidly Varying Flow
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...