Related Experiment Video
Updated: Jul 20, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Comparison between thermal recovery in women with Raynaud's Phenomenon and not diagnosed women using thermography
Abstract:
Thermography detects the infrared radiation emanated from bodies and transduces it in electrical analog signal. It has application as a complementary exam in several medical segments, including the reheating study to detect diseases like Raynaud's Phenomenon (RP). In this way, the aim of this study is to compare the heating behavior of the RP women and not diagnosed (ND) women for selection of diagnosis criteria. This retrospective study was undertaken in the city of Curitiba, Brazil. For the study, twenty-four volunteer women, with the age range of 30-70 years, were taken to participate of a survey, 12 of them have the clinical diagnostic of Secondary Raynauld's Phenomenon, and twelve women were not diagnosed. Volunteers answered an anamnesis and had the central body temperature measured. They were oriented to keep the hands free and to do not touch anything during 15 minutes for acclimatization. Then, the hands were immersed for 60 seconds in a container with water at 10 °C. New pictures were taken every five minutes during twenty minutes after the immersion. The heating curve of the right hand shows that RP women's hands are colder than ND women and are slower to reheat the temperature after cold stress. The ring (fourth finger) has a linear behavior in both hands. It was the coldest one and the slowest to reheat. Statistical difference was observed in critical times of reheating at 15 and 20 minutes after the cold stress. These results show that this finger could become a reference in studies to determine cutting points and to facilitate the clinical diagnosis of RP.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...