Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Reducing Line Loss01:18

Reducing Line Loss

390
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Nursing Diagnosis01:22

Nursing Diagnosis

4.1K
Following assessment, a nursing diagnosis is the next step in the nursing process. It begins after the nurse has collected and recorded the patient data. The purpose of diagnosing is to identify how the client responds to actual or potential health processes, identify factors that bestow or that cause health problems, the etiologies, and identify resources or strengths the individual, group, or community can draw on to prevent or resolve problems.
The nursing diagnosis focuses on evidence-based...
4.1K
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

550
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
550
Methods of reducing fever01:22

Methods of reducing fever

1.4K
The signs and symptoms of fever include hot and dry skin, flushed face, thirst, muscle aches, anorexia, headache, tachycardia, tachypnea, and fatigue. Elevated body temperature is reduced using two methods: pharmacological and nonpharmacological. Proper identification and treatment of the root cause of a fever is of utmost importance.
Pharmacological Methods of Reducing Fever:
1.4K
Formulating and Validating Nursing Diagnosis I01:26

Formulating and Validating Nursing Diagnosis I

3.9K
A nursing diagnosis is written when the nurse recognizes a cluster of essential patient data indicating health problems treated with independent nursing interventions. The standardized terminologies of a nursing diagnosis help nurses identify and treat patients' problems. Every electronic health record that uses nursing diagnosis must employ standard diagnostic terminology. Developing an efficient, individualized care plan begins with accurate nursing diagnoses.
There are thirteen domains...
3.9K
Documentation of Nursing Diagnosis01:10

Documentation of Nursing Diagnosis

1.8K
The nurse documents nursing diagnoses and enters them into the patient record. The identified patient's nursing diagnosis is either written out with a plan of care or entered into the electronic health record.
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Interactions between the aging brain and motor task complexity across the lifespan: balancing brain activity resource demand and supply.

Cerebral cortex (New York, N.Y. : 1991)·2023
Same author

The impact of cancer and chemotherapy during pregnancy on child neurodevelopment: A multimodal neuroimaging analysis.

EClinicalMedicine·2020
Same author

Motor cortex metabolite alterations in amyotrophic lateral sclerosis assessed in vivo using edited and non-edited magnetic resonance spectroscopy.

Brain research·2019
Same author

Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures.

Neuroradiology·2018
Same author

The nocebo effect challenges the non-medical infliximab switch in practice.

European journal of clinical pharmacology·2018
Same author

Method selection for sustainability assessments: The case of recovery of resources from waste water.

Journal of environmental management·2017

Related Experiment Video

Updated: Feb 2, 2026

Multimodality Diagnosis of Mesenteric Ischemia
05:07

Multimodality Diagnosis of Mesenteric Ischemia

Published on: July 21, 2023

1.3K

Myocardial Ischemia Diagnosis Using a Reduced Lead System.

A Aranda Hernandez, P Bonizzi, J Karel

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |November 17, 2018
    PubMed
    Summary
    This summary is machine-generated.

    A new statistical model effectively diagnoses acute myocardial infarction (AMI) using a simplified three-lead ECG system. This approach, incorporating novel pseudo-VCG parameters, offers potential for earlier and faster AMI detection in various monitoring settings.

    More Related Videos

    Induction of Myocardial Infarction and Myocardial Ischemia-Reperfusion Injury in Mice
    08:28

    Induction of Myocardial Infarction and Myocardial Ischemia-Reperfusion Injury in Mice

    Published on: January 19, 2022

    8.3K
    A Murine Closed-chest Model of Myocardial Ischemia and Reperfusion
    13:42

    A Murine Closed-chest Model of Myocardial Ischemia and Reperfusion

    Published on: July 17, 2012

    29.8K

    Related Experiment Videos

    Last Updated: Feb 2, 2026

    Multimodality Diagnosis of Mesenteric Ischemia
    05:07

    Multimodality Diagnosis of Mesenteric Ischemia

    Published on: July 21, 2023

    1.3K
    Induction of Myocardial Infarction and Myocardial Ischemia-Reperfusion Injury in Mice
    08:28

    Induction of Myocardial Infarction and Myocardial Ischemia-Reperfusion Injury in Mice

    Published on: January 19, 2022

    8.3K
    A Murine Closed-chest Model of Myocardial Ischemia and Reperfusion
    13:42

    A Murine Closed-chest Model of Myocardial Ischemia and Reperfusion

    Published on: July 17, 2012

    29.8K

    Area of Science:

    • Cardiology
    • Biomedical Engineering
    • Statistical Modeling

    Background:

    • Acute myocardial infarction (AMI) diagnosis relies heavily on electrocardiogram (ECG) interpretation.
    • Standard 12-lead ECG analysis can be complex, prompting research into simplified diagnostic approaches.
    • Identifying novel ECG features for improved AMI detection is crucial for timely intervention.

    Purpose of the Study:

    • To develop and validate a novel statistical model for diagnosing AMI.
    • To evaluate the diagnostic performance of a reduced three-lead ECG system.
    • To assess the utility of pseudo-vectorcardiography (pseudo-VCG) parameters in AMI diagnosis.

    Main Methods:

    • A statistical model was developed using features from a reduced three-lead ECG system.
    • Features included standard clinical parameters (ST elevation, T-wave maximum) and novel pseudo-VCG parameters.
    • The model was validated on 104 patients from the Physionet STAFF III database, including recordings during percutaneous coronary angioplasty (PTCA).

    Main Results:

    • Pseudo-VCG features alone showed slightly superior diagnostic performance (AUC 0.87) compared to standard features (AUC 0.85).
    • Combining pseudo-VCG features with ST elevation and T-wave maximum significantly improved diagnostic performance (AUC 0.95, sensitivity 89.6%, specificity 82.7%).

    Conclusions:

    • The proposed reduced lead system and feature set demonstrate significant potential for accurate AMI diagnosis.
    • This model could facilitate earlier and faster AMI diagnosis in long-term, ambulatory, and home monitoring scenarios.