During pregnancy, the pregnant mother undergoes significant physiological changes in order to accommodate the developing fetus. In recent years, arterial pulse wave has been widely used to reflect these physiological changes. The aim of this study was to investigate the changes of radial pulse and photoplethysmography (PPG) pulse waveform characteristic with gestational age in normal pregnant women. 40 pregnant women volunteers were recruited from February 2016 to September 2016 from the Haidian Maternal & Child Health Hospital in Beijing. Both radial pulses and PPG pulses were recorded simultaneously using a PowerLab data collection system at a sampling rate of 1000Hz for offline analysis. Their pulses were measured from each pregnant woman at three trimesters (first trimester between week 11-13; second trimester between week 20-22 and the third trimester between week 3739). Three waveform characteristics (total pulse area; pulse area1: the area before the notch position; pulse area2: the area after the notch position) were derived. The results showed that the total pulse area and pulse area2 from both radial and PPG pulses decreased significantly between two paired consecutive trimesters (all P<0.01, except the comparisons between the second and third trimesters for PPG pulses). In summary, this study has quantified the pulse waveform characteristic differences in terms of pulse areas between the three trimesters, providing useful scientific evidence to better understand the cardiovascular physiological changes during normal pregnancy.

Related Concept Videos

Effective Value of a Periodic Waveform01:07

Effective Value of a Periodic Waveform

The concept of effective value, the root mean square (RMS) value, is crucial in understanding electrical circuits and power delivery. This idea emerges from the necessity to measure the effectiveness of a voltage or current source in supplying power to a resistive load.
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
1.2K
Characteristics of Life01:23

Characteristics of Life

Biology is a natural science that studies life and living organisms, including their structure, function, development, interactions, evolution, distribution, and taxonomy. The field's scope is extensive and divided into several specialized disciplines, such as anatomy, physiology, ethology, genetics, and many more. All living things share a few key traits, including cellular organization, heritable genetic material and the ability to adapt/evolve, metabolism to regulate energy needs, the...
261.2K
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
2.1K
Pulse01:05

Pulse

The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
3.8K
Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.7K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.3K