The effect of increasing centrifugal acceleration/force and flow rate for varying column aspect ratios on separation

Aihua Peng1, Peter Hewitson2, Ian Sutherland3

  • 1State Key Laboratory of Biotherapy, West China Hospital, West China Medical School, Sichuan University, Chengdu, 610065, China.

Related Concept Videos

Column Efficiency: Rate Theory01:12

Column Efficiency: Rate Theory

The rate theory of chromatography provides quantitative insight into the shapes and widths of elution bands. These bands are based on the random-walk mechanism governing molecular migration within a column. The Gaussian profile of chromatographic bands arises from the cumulative effect of random molecular motions as they progress through the column.
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
993
Centrifugal Force01:06

Centrifugal Force

Pseudo forces, or fictitious forces, appear to act on an object in motion in a rotating frame of reference with respect to an inertial reference frame. These forces are not real forces but rather mathematical constructs and are introduced to simplify calculations in a non-inertial frame while using Newton's laws of motion. Common examples of pseudo forces include centrifugal, Coriolis, and Euler forces. These forces are essential in fields such as mechanics, astrophysics, and fluid...
4.1K
Increased pulse rate01:17

Increased pulse rate

Tachycardia is a condition marked by an abnormally fast or irregular heart rate, surpassing the typical resting rate. In adults, tachycardia is characterized by a pulse rate ranging from 100 to 180 beats per minute. The increased heart rate can result in inadequate blood flow to various body parts, ultimately diminishing the oxygen supply to organs and tissues.
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
1.2K
Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
13.6K
Gradually Varying Flow01:29

Gradually Varying Flow

Gradually varying flow (GVF) in open channels describes situations where water depth changes slowly along the channel due to factors like non-uniform bed slope, channel shape variations, or obstructions. This flow type occurs when the depth adjusts gradually to balance gravitational forces, shear forces, and energy requirements, resulting in a low rate of depth change.Characteristics of Gradually Varying FlowGVF is commonly observed in natural streams, rivers, and canals, where flow depth...
436
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
497