Cooperative Fault Diagnosis for Uncertain Nonlinear Multiagent Systems Based on Adaptive Distributed Fuzzy Estimators

Related Concept Videos

Cooperative Allosteric Transitions01:58

Cooperative Allosteric Transitions

Cooperative allosteric transitions can occur in multimeric proteins, where each subunit of the protein has its own ligand-binding site. When a ligand binds to any of these subunits, it triggers a conformational change that affects the binding sites in the other subunits; this can change the affinity of the other sites for their respective ligands. The ability of the protein to change the shape of its binding site is attributed to the presence of a mix of flexible and stable segments in the...
8.7K
Cooperative Allosteric Transitions01:58

Cooperative Allosteric Transitions

3.1K
Cooperative Allosteric Transitions01:58

Cooperative Allosteric Transitions

2.7K
Distributions to Estimate Population Parameter01:26

Distributions to Estimate Population Parameter

The accurate values of population parameters such as population proportion, population mean, and population standard deviation (or variance) are usually unknown. These are fixed values that can only be estimated from the data collected from the samples. The estimates of each of these parameters are sample proportion, the sample mean, and sample standard deviation (or variance). To obtain the values of these sample statistics, data are required that have particular distribution and central...
5.1K
Cooperative Binding of Transcription Regulators02:13

Cooperative Binding of Transcription Regulators

Transcriptional regulators bind to specific cis-regulatory sequences in the DNA to regulate gene transcription. These cis-regulatory sequences are very short, usually less than ten nucleotide pairs in length. The short length means that there is a high probability of the exact same sequence randomly occurring throughout the genome.  Since regulators can also bind to groups of similar sequences, this further increases the chances of random binding. Transcriptional regulators form...
7.4K
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
427