Related Experiment Video
Updated: Aug 18, 2026

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
An evaluation of precordial ultrasonic monitoring to avoid bends at altitude
R M Olson1, R W Krutz, G A Dixon
1KRUG International, Technology Services Division, San Antonio, Texas.
Abstract:
Several investigators have reported that intravascular bubbles can be detected in decompressed subjects before they develop bends. The altitude exposures were generally of short duration with a limited number of subjects. This important preliminary finding needed to be verified in a larger sampling of long duration altitude exposures. In this experiment, 32 subjects in 82 flights were taken to 27,500 ft simulated altitude for 8 h or until the subject developed mild but steady joint pain (bends). Many subjects took more than one flight. At altitude, the subjects were monitored for circulating bubbles by a team of well-trained, experienced technicians. It was determined that bubbles, clearly audible even to untrained observers, occurred in 77% of the flights in which the subjects developed bends. On the other hand, no bubbles were found in 61% of the flights in which the subjects remained bends free even though the subjects were monitored by more than one experienced technician. Therefore, at 27,500 ft ultrasonic monitoring will miss about 25% of the subjects who developed bends (false negatives) and will incorrectly identify a little less than half of the subjects who do not develop bends as potential benders (false positives).
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Holter Monitor: 24-Hour Monitoring