Reliability of Ultrasound-Guided One-Point Fixation for Zygomaticomaxillary Complex Fractures
Akimitsu Sato1, Yoshimichi Imai, Kenji Muraki
1Department of Plastic and Reconstructive Surgery, Tohoku University Graduate School of Medicine, Sendai, Japan.
Abstract:
This study aimed to analyze the precision and postoperative stability of ultrasound guided 1-point fixation on the zygomaticomaxillary buttress for the treatment of zygomaticomaxillary complex (ZMC) fractures. The authors analyzed 24 consecutive patients who underwent ultrasound-guided 1-point fixation for ZMC fractures without separation of the fracture at the frontal process of the zygomatic bone. The authors used titanium plates in the first 6 cases, and biodegradable plates in the remaining 18 cases. The authors obtained computed tomography images preoperatively, and again the first day after surgery (T1) and 6 months after the surgery (T2). The authors calculated vertical change (VC) and horizontal change (HC) of the zygoma on computed tomography. Precision was evaluated with T1 images. Stability was evaluated from T1 to T2, and titanium and biodegradable plates were compared. From T1 images, the mean VC and HC was 0.22° (range, 1.60°-1.08°) and 0.33° (range, 1.86°-1.03°), respectively. From T1 to T2, the mean VC and HC was 0.08° and 0.28°, respectively. Comparing the types of plates, the mean HC in the biodegradable plate group was 0.39°, which was significantly greater than that in the titanium plate group (mean -0.10°). However, as the degree of change was relatively small, this did not pose any clinical problems. Our findings suggest that ultrasound-guided 1-point fixation on the zygomaticomaxillary buttress provides accurate reduction on ZMC fractures without the separation of the frontal process of the zygomatic bone fracture. Sufficient stability was obtained, even with the use of biodegradable plates.
More Related Videos
07:44Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
Related Concept Videos
Reliability and Validity
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Distribution Reliability and Automation
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Carbon-dioxide Fixation
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
