Related Experiment Video
Updated: Feb 2, 2026

G2-seq: A High Throughput Sequencing-based Technique for Identifying Late Replicating Regions of the Genome
Published on: March 22, 2018
Performance of computerized cardiotocography-based short-term variation in late-onset small-for-gestational-age
Oliver Graupner1, Javier U Ortiz2, Bernhard Haller3
1Department of Obstetrics and Gynecology, University Hospital rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany. oliver.graupner@mri.tum.de.
Purpose:
Fetal Doppler changes are well characterized in early-onset small-for-gestational-age (SGA) and fetal growth restriction (FGR) but less well characterized where the condition is late-onset. The aim of the study was to evaluate the role of computerized CTG (cCTG)-based short-term variation (STV) in late-onset SGA and FGR as an additional monitoring modality and to establish STV reference ranges in late third trimester healthy pregnancies.
Methods:
Of 86 late-onset SGA fetuses diagnosed after 32 weeks, 66 were diagnosed with FGR. 138 healthy pregnancies acted as controls. All underwent umbilical artery pulsatility index (PI), middle cerebral artery PI, cerebroplacental ratio and mean uterine artery PI. cCTG recordings were analyzed by Sonicaid FetalCare software for STV calculation as described by Dawes/Redman.
Results:
Median interval between inclusion and delivery was 13 (interquantile range = 4-30) days in the FGR group, 22 (12-37) days in the SGA group and 25 (10-40) days in the control group. STV was not different between controls (11.2 ms, 9.7-13.1), late-onset SGA (11.2 ms, 8.1-12.6) and FGR (10.5 ms, 8.5-12.4) fetuses. A greater proportion of late-onset SGA fetuses had STV < 5th percentile (7/86) compared to controls (4/138) (8.1% vs. 2.9%, p = 0.077). In the control group a significant positive correlation was seen between STV, and 1-min (ρ = 0.195, p = 0.026), 5-min (ρ = 0.247, p = 0.004) and 10-min (ρ = 0.211, p = 0.014) Apgar values.
Conclusions:
We report no significant difference in STV median values between controls, SGA and FGR pregnancies. However, more SGA fetuses had a low STV compared to controls. Prospective longitudinal studies are needed to investigate if low STV is a useful surveillance method for late-onset FGR.
Related Concept Videos
Variation: Normal Distribution, Range, and Standard Deviation
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Development of the Sexual Organs in the Embryo and Fetus
Near the gonadal ridges, two duct systems are present: the mesonephric ducts (Wolffian ducts) and paramesonephric ducts (Müllerian ducts). These ducts form the basis for the...

