Evaluation of different methods of securing cellophane bands for portosystemic shunt attenuation
Michelle Robyn Joffe1, Evelyn Hall1, Christopher Tan1,2
1Sydney School of Veterinary Science, Faculty of Science, University of Sydney, Sydney, New South Wales, Australia.
Objective:
To compare mechanisms of and pressures at failure of 4 methods of securing 2 types of cellophane bands around a vein.
Study Design:
Ex vivo mechanical evaluation.
Methods:
Cellophane bands composed of 3 or 4 layers were applied around a cadaveric external jugular vein (EJV) to create 25% or 50% attenuation. These bands were secured with a medium or medium-large polymer locking ligation clip (PLLC), or a medium or medium-large titanium ligation clip (TLC). Sterile saline 0.9% was instilled into the lumen of the EJV until a pressure of 100 mm Hg was reached. Failure mechanism and luminal pressure at failure were compared between groups.
Results:
Medium clips failed less often than medium-large clips (P < .001) and consistently sustained 100 mm Hg without failing. Three-layer cellophane bands were 4.1 times more likely to fail than 4-layer bands (P = .003, CI 1.6-10.2) and failed at lower pressures (28.32 ± 3.59 mm Hg and 44.81 ± 6.51 mm Hg, respectively, P = .027). Failure rates of the cellophane band constructs did not differ whether secured with PLLC or with TLC (P = .635) or with 25% vs 50% attenuation (P = .780).
Conclusion:
A single medium clip withstood physiological forces and secured a cellophane band at up to 50% attenuation. A 3-layer cellophane band was more likely to fail compared with a 4-layer cellophane band.
Clinical Significance:
These ex vivo results provide evidence to support the application of a 4-layer cellophane band secured with a single medium PLLC or TLC for portosystemic shunt attenuation. A single medium PLLC should be used to eliminate computed tomography artifacts during postoperative evaluation of shunt closure.
More Related Videos
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
09:00The Rabbit Blood-shunt Model for the Study of Acute and Late Sequelae of Subarachnoid Hemorrhage: Technical Aspects
Published on: October 2, 2014
Related Concept Videos
Band Theory
The energy difference between these bands is known as the band gap.
Conductor, Semiconductor,...
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Energy Bands in Solids
Band Formation:
When atoms are brought close together, as in a solid, these discrete energy levels begin to split due to the overlap of electron orbitals from adjacent atoms. This split occurs because of the Pauli exclusion principle, which states...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Self-Evaluation: Self-Enhancement and Self-Verification