Correlation between choroidal thickness and intraocular pressure after 23-gauge vitrectomy for idiopathic epiretinal
Masahiro Ishida1, Takashi Wakakuri1, Yutaka Imamura1
1Department of Ophthalmology, Teikyo University School of Medicine, University Hospital Mizonokuchi, 5-1-1 Futago, Takatsu-ku, Kawasaki, Kanagawa 213-8507, Japan.
Aim:
To determine the relationship between the subfoveal choroidal thickness (CT) and intraocular pressure (IOP) following idiopathic epiretinal membrane (ERM) surgery.
Methods:
Retrospective observational case series of patients who had undergone 23-gauge vitrectomy for an ERM. The measurements of CT and IOP were done at the baseline and 1d, 1wk, 1, 3, 6, and 12mo after the surgery.
Results:
Forty-four eyes of 43 patients with a mean age of 69.8±9.5y were studied. The CT was 200.8±86.3 µm at the baseline, 210.1±83.5 µm at 1d, 213.2±85.4 µm at 1wk, 203.1±84.0 µm at 1mo, 197.5±85.5 µm at 3mo, 197.7±84.0 µm at 6mo, and 191.2±86.8 µm at 12mo after surgery. The CT on day 1 and week 1 after the surgery was significantly thicker than that at the baseline CT (P=0.0023 and P<0.0001). The CT at 12mo after surgery was significantly thinner than the baseline (P=0.0062). The IOP on day 1 and week 1 were significantly lower than the baseline (P<0.0001 and P=0.0042). The IOP at 1, 3, 6, and 12mo after surgery were significantly higher than the baseline IOP (P=0.0087, P=0.0023, P<0.00051, and P<0.0001). The rates of changes in the CT between baseline and day 1 and week 1 were significantly and negatively correlated with the rates of change in the IOP (P<0.0001 and P=0.046). In the group with the IOP change rate of -30% or less at 1d postoperatively, the change rate of CT was -21.1% to 31.2% (9.8%±12.4%) and in the group of -29% or more, it was -8.9% to 28.0% (2.6%±8.9%). The change rate of CT in the group with the IOP change rate of -30% or less was significantly higher than the group of -29% or more (P=0.016).
Conclusion:
CT increases soon after the ERM surgery which is probably due to the transient hypotony, showing that IOP may be a significant confounding factor for CT.
Related Concept Videos
Pressure Gauges
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Vapor Pressure