Non-invasive measurement of reservoir pressure parameters from brachial-cuff blood pressure waveforms
Xiaoqing Peng1, Martin G Schultz1, Dean S Picone1
1Menzies Institute for Medical Research, University of Tasmania, Hobart, Tasmania, Australia.
Abstract:
Reservoir pressure parameters [eg, reservoir pressure (RP) and excess pressure (XSP)] are biomarkers derived from blood pressure (BP) waveforms that have been shown to predict cardiovascular events independent of conventional cardiovascular risk markers. However, whether RP and XSP can be derived non-invasively from operator-independent cuff device measured brachial or central BP waveforms has never been examined. This study sought to achieve this by comparison of cuff reservoir pressure parameters with intra-aortic reservoir pressure parameters. 162 participants (aged 61 ± 10 years, 72% male) undergoing coronary angiography had the simultaneous measurement of cuff BP waveforms (via SphygmoCor XCEL, AtCor Medical) and intra-aortic BP waveforms (via fluid-filled catheter). RP and XSP derived from cuff acquired brachial and central BP waveforms were compared with intra-aortic measures. Concordance between brachial-cuff and intra-aortic measurement was moderate-to-good for RP peak (36 ± 11 vs 48 ± 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.71-0.82), and poor-to-moderate for XSP peak (28 ± 10 vs 24 ± 9 mm Hg, P < 0.001; ICC 0.49, 95% CI: 0.35-0.60). Concordance between central-cuff and intra-aortic measurement was moderate-to-good for RP peak (35 ± 9 vs 46 ± 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.70-0.82), but poor for XSP peak (12 ± 3 vs 24 ± 9 mm Hg, P < 0.001; ICC 0.12, 95% CI: -0.13 to 0.31). In conclusion, both brachial-cuff and central-cuff methods can reasonably estimate intra-aortic RP, whereas XSP can only be acceptably derived from brachial-cuff BP waveforms. This should enable widespread application to determine the clinical significance, but there is significant room for refinement of the method.
Related Concept Videos
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Blood Pressure