Accuracy of a Smartphone-based Autorefractor Compared with Criterion-standard Refraction
V Swetha E Jeganathan1, Nita Valikodath1, Leslie M Niziol1
1Department of Ophthalmology and Visual Sciences, W. K. Kellogg Eye Center, University of Michigan, Ann Arbor, Michigan.
A low-cost smartphone autorefractor showed clinically significant differences from subjective refraction but demonstrated good usability. This portable device may improve eye care access for underserved populations needing vision correction.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Public Health
Background:
- Uncorrected refractive error is a global health issue, disproportionately affecting low-income populations with limited access to eye care services and affordable eyeglasses.
- Professional eye care and corrective lenses remain inaccessible for many, highlighting the need for innovative, low-cost solutions.
Purpose of the Study:
- To assess the accuracy and usability of a novel, portable, smartphone-based autorefractor (Netra) in adult participants.
- To compare the performance of the Netra device against standard subjective refraction methods.
Main Methods:
- A cross-sectional study involved 87 adult participants, comparing the Netra autorefractor with manifest and cycloplegic refraction.
- Spherical equivalent was calculated for each refraction method, and differences were analyzed using linear mixed regression models.
- A validated questionnaire assessed the usability and ease of use of the portable autorefractor on a 100-point scale.
Main Results:
- The mean spherical equivalent measured by Netra was -2.76 D, compared to -2.49 D by manifest refraction, with a mean difference of -0.27 D.
- The mean absolute difference between Netra and subjective refraction was 0.69 D, which was statistically significant.
- Participants reported an average ease-of-use score of 75.4 ± 19.8 for the Netra device, indicating good acceptance.
Conclusions:
- The portable smartphone autorefractor demonstrated clinically significant differences from subjective refraction but showed good patient acceptance.
- The Netra device's usability suggests it could be a valuable tool for expanding eye care access, particularly in resource-limited settings.
- This technology holds potential for improving refractive error detection where trained eye care professionals are scarce.
Related Concept Videos
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Potential-Energy Criterion for Equilibrium