Related Experiment Video
Updated: Feb 2, 2026

A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
Published on: November 13, 2016
Noise-Assisted Multivariate EMD-Based Mean-Phase Coherence Analysis to Evaluate Phase-Synchrony Dynamics in Epilepsy
Abstract:
Spatiotemporal evolution of synchrony dynamics among neuronal populations plays an important role in decoding complicated brain function in normal cognitive processing as well as during pathological conditions such as epileptic seizures. In this paper, a non-linear analytical methodology is proposed to quantitatively evaluate the phase-synchrony dynamics in epilepsy patients. A set of finite neuronal oscillators was adaptively extracted from a multi-channel electrocorticographic (ECoG) dataset utilizing noise-assisted multivariate empirical mode de-composition (NA-MEMD). Next, the instantaneous phases of the oscillatory functions were extracted using the Hilbert transform in order to be utilized in the mean-phase coherence analysis. The phase-synchrony dynamics were then assessed using eigenvalue decomposition. The extracted neuronal oscillators were grouped with respect to their frequency range into wideband (1-600 Hz), ripple (80-250 Hz), and fast-ripple (250-600 Hz) bands in order to investigate the dynamics of ECoG activity in these frequency ranges as seizures evolve. Drug-refractory patients with frontal and temporal lobe epilepsy demonstrated a reduction in phase-synchrony around seizure onset. However, the network phase-synchrony started to increase toward seizure end and achieved its maximum level at seizure offset for both types of epilepsy. This result suggests that hyper-synchronization of the epileptic network may be an essential self-regulatory mechanism by which the brain terminates seizures.
Related Concept Videos
Phase Transitions
Phase Diagrams
Phase Transitions: Sublimation and Deposition
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...

