Performance and variability of QuantiFERON Gold Plus assay associated with phlebotomy type
Saroochi Agarwal1, Duc T Nguyen1, Justin D Lew1
1Department of Pathology and Genomic Medicine, Houston Methodist Research Institute, Houston, Texas, United States of America.
The QuantiFERON Gold Plus assay showed more positive tuberculosis infection results than the Gold assay. Agreement between the two methods was lower than expected, indicating potential variability in results.
Area of Science:
- Infectious Diseases
- Clinical Diagnostics
- Tuberculosis Screening
Background:
- The QuantiFERON Gold Plus (Plus) assay offers two blood collection methods: direct in-tube (Plus direct) and blood transfer from a lithium heparin tube (Plus transfer).
- Limited data exists comparing QuantiFERON Gold In-Tube (Gold) results with the Plus assay based on blood collection methods.
Purpose of the Study:
- To compare the performance of QuantiFERON Gold (Gold) and QuantiFERON Gold Plus (Plus) assays using direct in-tube and blood transfer methods for tuberculosis infection screening.
- To evaluate the agreement between different blood collection methods for the Plus assay and the Gold assay.
Main Methods:
- A study was conducted with 300 high-risk healthcare workers undergoing annual tuberculosis infection screening.
- Blood samples were collected concurrently for QuantiFERON Gold In-Tube (Gold), QuantiFERON Gold Plus direct in-tube (Plus direct), and QuantiFERON Gold Plus transfer (Plus transfer) assays.
Main Results:
- The proportion of positive results was 10% for Gold, 12% for Plus direct, and 17% for Plus transfer.
- Agreement between Gold and Plus direct was 91% (κ = 0.56), Gold and Plus transfer was 91% (κ = 0.59), and Plus direct and Plus transfer was 85% (κ = 0.37).
Conclusions:
- The Gold Plus assay yielded a higher proportion of positive tuberculosis infection results compared to the Gold assay in a low-prevalence setting.
- Unexpectedly low agreement was observed between the assays and collection methods, highlighting potential variability with blood transfer protocols.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Graphs of Equations in Two Variables
Variables Affecting Phosphorescence and Fluorescence
Work and Energy for Variable Forces