Related Experiment Video
Updated: Feb 2, 2026

Extraction and Characterization of Surfactants from Atmospheric Aerosols
Published on: April 21, 2017
Disulphide Bridges in Surfactant Protein B Analogues Affect Their Activity in Synthetic Surfactant Preparations
Oihana Basabe-Burgos1, Jan Johansson2, Tore Curstedt3
1Department of Neurobiology, Care Sciences and Society, Division of Neurogeriatrics, Karolinska Intitutet, Huddinge, Sweden, oihana.basabe.burgos@ki.se.
Background:
Limited supply and complicated manufacturing procedure of animal-derived surfactants make the development of synthetic surfactants warranted. The synthesis of surfactant protein (SP)-B and SP-C is complicated and several analogues have been developed. Mini-BLeu is an analogue that corresponds to the first and last helix of SP-B joined by a loop and linked by 2 disulphide bridges. SP-C33Leu is an SP-C analogue that can be cost-efficiently produced, but no such analogue has yet been described for SP-B.
Objective:
To design short SP-B analogues which lack disulphide bridges, are easy to produce and are efficacious in a preterm rabbit fetus model of neonatal RDS.
Methods:
Synthetic surfactants were prepared by adding 2 or 8% (w/w) of synthetic variants of Mini-B27, similar to Mini-BLeu but with a short loop, or different peptides covering helix 1 of SP-B to 2% (w/w) of SP-C33Leu in 80 mg/mL of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine/egg yolk phosphatidylcholine/1-palmitoyl-2-oleoyl-sn-glycero-3-phosphoglycerol, 50: 40: 10 (by weight). Premature newborn rabbit fetuses were treated with 200 mg/kg of the surfactant preparations and ventilated with defined pressures for 30 min without positive end-expiratory pressure. Tidal volumes were registered during the experiments and lung gas volumes were measured at the end of the ventilation period.
Results:
Synthetic surfactant containing the Mini-B27 analogue with 2 disulphides gives similar lung gas volumes as treatment with an animal-derived surfactant preparation, but all other SP-B analogues gave lower lung gas volumes. All synthetic surfactants studied gave no significant differences in compliances except the surfactant containing the Mini-B27 analogue without cysteines that performed somewhat better at 30 min.
Conclusion:
The helix-loop-helix SP-B analogues tested in this study require the presence of 2 disulphide bridges for optimal activity in a rabbit RDS model.
More Related Videos
06:31Studying Surfactant Effects on Hydrate Crystallization at Oil-Water Interfaces Using a Low-Cost Integrated Modular Peltier Device
Published on: March 18, 2020
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Wheatstone Bridge
Thus, for accurate resistance measurements, a...
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Role of Affect in Interpersonal Attraction
Cross-bridge Cycle
The Influence of Affect on Cognition