Oxygen Monitoring Equipment for Sewage-Sludge Composting and Its Application to Aeration Optimization
Guodi Zheng1,2, Yuewei Wang3,4, Xiankai Wang5,6
1Center for Environmental Remediation, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101, China. zhenggd@igsnrr.ac.cn.
Abstract:
Oxygen is an important parameter for organic-waste composting, and continuous control of the oxygen in a composting pile may be beneficial. The oxygen consumption rate can be used to measure the degree of biological oxidation and decomposition of organic matter. However, without having a real-time online device to monitor oxygen levels in the composting pile, the adjustment and optimization of the composting process cannot be directly implemented. In the present study, we researched and developed such a system, and then tested its stability, reliability, and characteristics. The test results showed that the equipment was accurate and stable, and produced good responses with good repeatability. The equilibrium time required to detect oxygen concentration in the composting pile was 50 s, and the response time for oxygen detection was less than 2 s. The equipment could monitor oxygen concentration online and in real time to optimize the aeration strategy for the compost depending on the concentration indicated by the oxygen-measuring equipment.
More Related Videos
Related Concept Videos
Leveling Equipment
Personal Protective Equipment
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated....
Optimal Foraging