Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
A Comparison of Various Cervical Muscle Strength Testing Methods Using a Handheld Dynamometer
David A Krause1, Kelsey A Hansen2, Matthew J Hastreiter2
1Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota.
Background::
Cervical muscle strength, proposed as a modifiable risk factor in concussions, can be assessed using various methods. The purpose of this study was to compare the reliability and force outputs of 3 methods that use handheld dynamometry (HHD) for assessing cervical muscle strength.
Hypothesis::
All 3 testing methods are reliable, and force outputs are significantly different between methods.
Study Design::
Repeated-measures reliability.
Level Of Evidence::
Level 5.
Methods::
The study used a convenience sample of 30 participants. HHD "make tests" for cervical extension, flexion, and right and left side bending were performed using lying push tests, sitting push tests, and sitting pull tests. A sole examiner performed all tests. Two testing sessions were conducted 1 week apart. Analysis included intraclass correlation coefficients (ICCs), repeated-measures analyses of variance (α = 0.05) with post hoc Bonferroni tests, and minimal detectable change (MDC) calculations.
Results::
All testing methods were reliable; the lying push test had the greatest point estimate values (ICC, 0.89-0.95). Significant differences in force were found between the 3 testing methods. The MDC was most sensitive for the lying push method.
Conclusion::
Of the 3 cervical muscle testing methods investigated, the lying position with a push test had the largest ICC according to the point estimate and the most sensitive MDC. Force values between the 3 methods were significantly different, which suggests that consistent testing methods should be used.
Clinical Relevance::
Results from this study support the clinical use of an HHD "make test" in a lying position for assessing cervical muscle strength. The test is reliable and more sensitive to change compared with tests in a seated position.
More Related Videos
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Non-destructive Tests for Concrete Strength
Peripherally and Centrally Acting Muscle Relaxants: A Comparison
Centrally acting muscle relaxants can be further divided into spasmolytic and antispasmodic drugs. Spasmolytic...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...