Influence of moisture variation on the performance of Raman spectroscopy in quantitative pharmaceutical analyses
Md Nayeem Hossain1, Benoît Igne2, Carl A Anderson3
1Duquesne University Graduate School of Pharmaceutical Sciences, Pittsburgh, PA 15282, United States.
Abstract:
To develop a robust quantitative calibration model for spectroscopy, different sources of variability that are not directly related to the components of interest should be included in the calibration samples; this variability should be similar to that which is anticipated during validation and routine operation. Moisture content of pharmaceutical samples can vary as a function of supplier, storage conditions, geographic origin or seasonal variation. Additionally, some pharmaceutical operations (e. g., wet granulation) cause exposure of excipients and API to water. Although water is a weak Raman scatterer, moisture variability has an indirect effect on analytical model performance. Because many pharmaceutical components have intrinsic fluorescent characteristics (with broad spectral features), moisture variability may cause spectral artifacts in the form of baseline variation associated with fluorescence quenching. This work investigates the deleterious effects of water quenching on quantitative prediction accuracy of a multivariate calibration algorithm for Raman spectroscopy. To demonstrate this, a formulation composed of acetaminophen, lactose, microcrystalline cellulose, HPMC and magnesium stearate was used. Tablets were manufactured using laboratory scale equipment. A full-factorial design was used to vary acetaminophen (5 levels), and excipient ratios (3 levels) to generate tablets for calibration and testing. Tablet moisture variation was introduced by placing samples in different humidity chambers. Significant spectral effects arising from fluorescence were identified in the Raman spectra and due to moisture variation: the fluorescence related spectral variability caused substantial degradation of the prediction performance for API. The work demonstrated that accounting for moisture variation during method development reduced the prediction error of the multivariate prediction model.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Pharmaceutical Equivalents
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...