Description of an air temperature sensor based on O2 absorption spectroscopy
Marlon Diaz1, Parashu R Nyaupane1, Daniel Monteagudo1
1Department of Chemistry & Biochemistry, Baylor University, Waco, TX 76798, United States of America.
Abstract:
In this paper, we describe in detail an assembled open-path optical cavity to act as a temperature sensor of air. A metal absorption cell in a temperature-regulated tube furnace is placed at the center of an optical cavity. The optical cavity consists of two mirrors, two nitrogen buffer sleeves, and the open cell. The air is injected through a fitting in one extreme of the metal tube and travels half the tube length through a channel in the wall of the tube. The channel directs the air towards the center of the cell. The air flowing is heated at the temperature of the metal tube in contact with the furnace. The heated air injected at the center of the tube, flows towards the open extremes of the tube. The nitrogen buffer sleeves protect the mirrors from the heated air. The temperature of the air flowing through the tube is determined by measuring the absorption of the A band of oxygen as a function of the wavenumber in the 769-755 nm wavelength range. The absorption technique is phase-shift cavity ring down spectroscopy. To obtain the temperature, the energy of the lower rotational state for eleven selected rotational transitions is linearly fitted to a logarithmic function that contains the relative intensity of the rotational transition, the initial and final rotational quantum numbers and the energy of the transition. Accuracy of the measurement is determined by comparing the calculated temperature from the spectra with the analog reading of the temperature-regulated tube furnace. This technique is proposed for exhaust air temperature measurements of combustion chambers and cooling air after passing through the blades of a turbine.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Molecular Spectroscopy: Absorption and Emission
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...