Related Experiment Video
Updated: Feb 2, 2026

Assessing Murine Resistance Artery Function Using Pressure Myography
Published on: June 7, 2013
Blood pressure waveform contour analysis for assessing peripheral resistance changes in sepsis
Shaun Davidson1, Chris Pretty2, Joel Balmer2
1Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand. shaun.davidson@canterbury.ac.nz.
Background:
This paper proposes a methodology for helping bridge the gap between the complex waveform information frequently available in an intensive care unit and the simple, lumped values favoured for rapid clinical diagnosis and management. This methodology employs a simple waveform contour analysis approach to compare aortic, femoral and central venous pressure waveforms on a beat-by-beat basis and extract lumped metrics pertaining to the pressure drop and pressure-pulse amplitude attenuation as blood passes through the various sections of systemic circulation.
Results:
Validation encompasses a comparison between novel metrics and well-known, analogous clinical metrics such as mean arterial and venous pressures, across an animal model of induced sepsis. The novel metric Ofe → vc, the direct pressure offset between the femoral artery and vena cava, and the clinical metric, ΔMP, the difference between mean arterial and venous pressure, performed well. However, Ofe → vc reduced the optimal average time to sepsis detection after endotoxin infusion from 46.2 min for ΔMP to 11.6 min, for a slight increase in false positive rate from 1.8 to 6.2%. Thus, the novel Ofe → vc provided the best combination of specificity and sensitivity, assuming an equal weighting to both, of the metrics assessed.
Conclusions:
Overall, the potential of these novel metrics in the detection of diagnostic shifts in physiological behaviour, here driven by sepsis, is demonstrated.
More Related Videos
Related Concept Videos
Assessing Blood pressure in the Leg
Preparation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: