Feasibility of PET/CT system performance harmonisation for quantitative multicentre 89Zr studies
Andres Kaalep1, Marc Huisman2, Terez Sera3,4
1Department of Medical Technology, North Estonia Medical Centre Foundation, J. Sutiste Str 19, 13419, Tallinn, Estonia. kaalep@gmail.com.
Quantitative harmonisation of zirconium-89 (89Zr) PET/CT imaging is feasible across multiple scanners. Proper calibration and reconstruction ensure consistent results, facilitating multicenter studies.
Area of Science:
- Nuclear Medicine
- Medical Imaging
- Radiochemistry
Background:
- Positron Emission Tomography/Computed Tomography (PET/CT) enables quantitative imaging.
- Zirconium-89 (89Zr) is a radioisotope increasingly used for PET imaging, particularly in oncology.
- Standardization of 89Zr PET/CT is crucial for reliable quantitative analysis.
Purpose of the Study:
- To assess the variability in quantitative performance of 89Zr PET/CT scanners.
- To evaluate the feasibility of quantitative harmonization for 89Zr PET/CT imaging.
Main Methods:
- Eight EANM EARL-accredited PET/CT systems were used.
- Phantom studies with uniform and NEMA NU2-2007 body phantoms were conducted.
- Standard Uptake Value (SUV) accuracy and Recovery Coefficients (RC) were determined using SUVmean, SUVmax, and SUVpeak metrics.
Main Results:
- All systems showed similar Recovery Coefficient (RC) curves.
- Five systems achieved comparable recoveries after SUV bias correction.
- SUVpeak demonstrated the lowest sensitivity to noise and reconstruction variations.
Conclusions:
- Quantitative harmonization of 89Zr PET/CT is achievable with proper cross-calibration and harmonized reconstruction.
- An accreditation program for PET/CT scanners would support multicenter 89Zr quantitative studies.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Case Studies
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...