ADAMTS13 protects mice against renal ischemia-reperfusion injury by reducing inflammation and improving endothelial

Suhan Zhou1, Shan Jiang1, Jie Guo1

  • 1Kidney Disease Center of First Affiliated Hospital, and Department of Physiology, School of Basic Medical Sciences, Zhejiang University School of Medicine , Hangzhou , China.

Related Concept Videos

Inflammation01:38

Inflammation

Overview
62.1K
Serum Studies: Renal Function Tests01:24

Serum Studies: Renal Function Tests

Renal function tests are crucial for assessing kidney health, monitoring disease progression, and evaluating the kidneys' efficiency in waste elimination, fluid balance, and electrolyte regulation. These tests offer critical insights into kidney function, even though routine measurements may appear normal until there is a significant decline in the glomerular filtration rate or GFR. Typically, signs of kidney impairment only become evident when the GFR falls to about 50% of its normal level.
435
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
391
Protection of Alcohols02:31

Protection of Alcohols

This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
795
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
444