Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Advancing Pathogen Detection and Disease Assessment in Real-Time Using M-ROSE
Published on: March 1, 2024
Monitoring Hearing in an Infectious Disease Clinic with mHealth Technologies
Marize Brittz1, Barbara Heinze1, Faheema Mahomed-Asmail1
1Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa.
Background:
Decentralized detection and monitoring of hearing loss can be supported by new mobile health technologies using automated testing that can be facilitated by minimally trained persons. These may prove particularly useful in an infectious disease (ID) clinic setting where the risk of hearing loss is high.
Purpose:
To evaluate the clinical utility of mobile and automated audiometry hearing health technology in an ID clinic setting.
Research Design:
Smartphone-automated pure-tone audiometry (PTA) (hearTest™) and speech-in-noise testing (SA English digits-in-noise [DIN] test) were compared with manual audiometry (2, 4, and 8 kHz). Smartphone-automated PTA and the DIN test were repeated to determine the test-retest reliability.
Study Sample:
Two hundred subjects (73% female and 27% male) were enrolled. Fifty participants were retested with the smartphone applications. Participants ranged from an age of 18 to 55 years with a mean age of 44.4 (8.7 standard deviation).
Data Analysis:
Threshold comparisons were made between smartphone audiometry testing and manual audiometry. Smartphone-automated PTA, manual audiometry, and test-retest measures were compared (Wilcoxon signed ranked test). Spearman rank correlation test was used to determine the relationship between the smartphone applications and manual audiometry, as well as for test-retest reliability.
Results:
Within all participants, 88.2% of thresholds corresponded within 10 dB or less between smartphone audiometry and manual audiometry. There was a significant difference (p < 0.05) between the right ear at 4 and 8 kHz and in the left ear at 2 and 4 kHz between smartphone and manual audiometry, respectively. No significant difference was noted (p < 0.05) between test and retest measures of smartphone technology.
Conclusions:
Smartphone audiometry with calibrated headphones provides reliable results in an ID clinic setting and can be used as a baseline and monitoring tool at ID clinics.
Related Concept Videos
Hearing
Chronic Kidney Disease II: Clinical Manifestations
Coronary Artery Disease III: Clinical Manifestations
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

