Related Experiment Video
Updated: Feb 2, 2026

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Determination of the optical turbulence parameters from the adaptive optics telemetry: critical analysis and on-sky
Abstract:
It has been demonstrated by several authors that the optical turbulence parameters associated with a given adaptive optics (AO) run-the seeing angle and outer scale-can be determined from a statistical analysis of the commands of the system's deformable mirror (DM). The higher the accuracy on these parameters, the more we can make use of them, allowing for instance a better estimation of the seeing statistics at the telescope location or a more accurate assessment of the performance of the AO system. In the context of a point spread function reconstruction project (PSF-R) for the W. M. Keck observatory AO system, we decided to identify, in the most exhaustive way, all the sources of systematic and random errors affecting the determination of the seeing angle and outer scale from the DM telemetry, and find ways to compensate/mitigate these errors to keep them under 10%. The seeing estimated using our improved DM-seeing method was compared with more than 70 nearly simultaneous seeing measurements from open-loop PSFs on the same optical axis, and with independent seeing-monitor measurements acquired at the same time but far from the telescope (DIMM/MASS): the correlation with the open-loop PSF is very good (the error is about 10%), validating the DM-seeing method for accurate seeing determination, while it is weak and sometimes completely uncorrelated with the DIMM/MASS seeing monitor data. We concluded that DM-based seeing can be very accurate if all the error terms are considered in the DM data processing, but that seeing taken from non-collocated seeing monitors is of no use even when moderate accuracy is required.
Related Concept Videos
Properties of Enantiomers and Optical Activity
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
Laminar and Turbulent Flow
Turbulent Flow

