Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Errors and Mistakes in Surveying01:19

Errors and Mistakes in Surveying

693
Errors and mistakes in surveying refer to inaccuracies in measurements and data recording. The errors are deviations from the actual value caused by human sensory limitations, equipment flaws, or environmental effects. These errors are typically unintentional and can result from the inherent imperfections in the instruments used, atmospheric conditions, or the observer’s inability to perceive exact measurements. On the other hand, mistakes are caused by the surveyor's lack of...
693
Distance Corrections01:15

Distance Corrections

290
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
290
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

468
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
468
Power Factor Correction01:20

Power Factor Correction

540
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
540
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
tRNA Activation02:26

tRNA Activation

22.9K
Aminoacyl-tRNA synthetases are present in both eukaryotes and bacteria. Though eukaryotes have 20 different aminoacyl-tRNA synthetases to couple to 20 amino acids, many bacteria do not have genes for all of these aminoacyl-tRNA synthetases. Despite this, they still use all 20 amino acids to synthesize their proteins. For instance, some bacteria do not have the gene encoding the enzyme that couples glutamine with its partner tRNA. In these organisms, one enzyme adds glutamic acid to all of the...
22.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Case Report: Loss-of-function TRPM4 mutation p.L91Δ implicated in progressive cardiac conduction defect.

Frontiers in physiology·2025
Same author

A Meta-Analysis of Clinical and Echocardiographic Outcomes of Physiological Versus Conventional Pacing.

Biomedicines·2025
Same author

His Bundle Pacing Improves Left Ventricular Function in Patients with Bradyarrhythmia or Tachy-Brady Syndrome and Permanent Atrial Fibrillation: A Retrospective Analysis.

Journal of clinical medicine·2025
Same author

The Influence of Interatrial Conduction Disorders on Atrial Mechanical Function - Atrial Strain and Pulmonary Veins Reversal Flow in Patients with COVID-19.

Reviews in cardiovascular medicine·2025
Same author

His Bundle Pacing and Left Bundle Branch Pacing in Patients with Heart Failure.

Biomedicines·2024
Same author

Experience with transvenous lead extraction of His bundle pacing leads.

Kardiologia polska·2024

Related Experiment Video

Updated: Feb 2, 2026

Surgical Correction for Pediatric Epiblepharon and Trichiasis
03:59

Surgical Correction for Pediatric Epiblepharon and Trichiasis

Published on: July 8, 2025

581

Mistakes should be corrected…

Jacek Gajek1, Agnieszka Slawuta2

  • 1Department of Clinical Nursing, Wroclaw Medical University, Bartla 5, Wroclaw, Poland.

European Heart Journal
|November 22, 2018
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
05:46

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity

Published on: September 20, 2024

828
Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
07:06

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

Published on: March 29, 2022

3.3K

Related Experiment Videos

Last Updated: Feb 2, 2026

Surgical Correction for Pediatric Epiblepharon and Trichiasis
03:59

Surgical Correction for Pediatric Epiblepharon and Trichiasis

Published on: July 8, 2025

581
Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
05:46

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity

Published on: September 20, 2024

828
Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
07:06

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

Published on: March 29, 2022

3.3K