Purpose:
The reliability of assessment of the artery of Adamkiewicz before the aortic repair is highly dependent on the display of the continuity of this artery with the aorta, mainly around the vertebral pedicle, by computed tomography angiography (CTA). We hypothesized that the sharp filter kernel can improve visualization of this continuity of the vessel structure because of its edge enhancement and high-spatial resolution. This study was performed to compare the subjective and objective image quality of spinal CTA reconstructed with sharp and smooth filter kernels.
Methods:
We retrospectively reviewed 40 consecutive patients who had undergone 80-kV CTA to detect the artery of Adamkiewicz before aortic repair. We measured the CT number and the contrast-to-noise ratio of the anterior spinal artery to the spinal cord. Furthermore, the continuity of the artery of Adamkiewicz was evaluated using a 3-point scale (2 points, absolute; 0 points, undetectable).
Results:
CTA with the sharp filter kernel showed a significantly higher CT number and contrast-to-noise ratio of the spinal artery than did CTA with the smooth filter kernel (P < .001 for both). Moreover, the sharp filter kernel showed a significantly higher continuity of the artery of Adamkiewicz with the aorta than did the smooth filter kernel (P < .001).
Conclusions:
The sharp filter kernel significantly improved the image quality in low-tube-voltage CTA for the assessment of the artery of Adamkiewicz. Thus, CTA with the sharp filter kernel can generate a high-confidence level in the evaluation of the artery of Adamkiewicz.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active Filters
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Fischer Projections
Newman Projections
The organic molecules rotate across the single bonds leading to numerous temporary three-dimensional structures of varying energy known as...