Related Experiment Video
Updated: Feb 2, 2026

Development of a Nose-only Inhalation Toxicity Test Chamber That Provides Four Exposure Concentrations of Nano-sized Particles
Published on: March 18, 2019
Size-dependent characteristics of diurnal particle concentration variation in an underground subway tunnel
Sang-Hee Woo1,2, Jong Bum Kim2, Gwi-Nam Bae3
1School of Mechanical Engineering, Hanyang University, Seoul, 04763, Republic of Korea.
Abstract:
Understanding characteristics of diurnal particle concentration variation in an underground subway tunnel is important to reduce subway passengers' exposure to high levels of toxic particle pollution. In this study, real-time particle monitoring for eight consecutive days was done at a shelter located in the middle of a one-way underground subway tunnel in Seoul, Republic of Korea, during the summer of 2015. Particle mass concentration was measured using a dust monitor and particle number concentration using an optical particle counter. From the diurnal variations in PM10, PM2.5, and PM1, concentrations of particles larger than 0.54 μm optical particle diameter were affected by train frequency whereas those of particles smaller than 0.54 μm optical particle diameter were not changed by train frequency. Number concentration of particles smaller than 1.15 μm optical particle diameter was dependent on outdoor ambient air particle concentration level, whereas that of particles larger than 1.15 μm optical particle diameter was independent of outdoor ambient air due to low ventilation system transmission efficiency of micrometer-sized particles. In addition, an equation was suggested to predict the diurnal particle concentration in an underground tunnel by considering emission, ventilation, and deposition effects.
Related Concept Videos
The Integrated Rate Law: The Dependence of Concentration on Time
Basic Postulates of Kinetic Molecular Theory: Particle Size, Energy, and Collision
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Factors Affecting Dissolution: Particle Size and Effective Surface Area
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...

