Related Experiment Video
Updated: Feb 2, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Cardiac computed tomography previous to atrial fibrillation ablation - effects of technological improvements and
Hugo Marques1, Pedro de Araújo Gonçalves2, António Miguel Ferreira3
1Unidade de Imagem Cardiovascular por TC e RM (Unica), Centro de Imagiologia, Hospital da Luz, Lisboa, Portugal; Serviço de Radiologia, Hospital de Santa Marta, CHLC, Lisboa, Portugal; Nova Medical School, Lisboa, Portugal.
Background:
Cardiac computed tomography (CT) can provide a precise tridimentional anatomic map and exclude intra-cardiac thrombus. We aimed to access the impact of CT protocol optimization and technological evolution on the contrast and radiation dose as well as on image quality previous to atrial fibrillation (AF) ablation.
Methods:
From a prospective registry of consecutive patients who underwent cardiac CT in a single center, we selected 270 patients in whom the CT was done for evaluation prior to AF ablation and they were distributed in 3 groups: Group1: the first 150 patients included; Group2: the last 60 patients performed with the same CT scanner; Group3: the first 60 exams performed with the new CT scanner. Quality of the protocol was access based on radiation dose, contrast volume used, the use of a second (delayed) acquisition, and on quantitative image quality analisis (signal to noise and contrast to noise ratios; density homogeneity racio between LA and LAA).
Results:
We found a significant radiation dose as well as contrast dose reduction between the first and last subgroups (G1: 5,6mSv and 100ml; G2: 1,3mSv and 90ml; G3: 0,6mSv and 65ml). Even though group 3 had less radiation and contrast used it still had better quantitative image quality (signal/noise of 13,5; contrast/noise 14,8; density homogeneity racio of 0,92).
Conclusion:
Protocol optimization and technology both contributed to significant lower radiation dose and contrast volume used on cardiac CTs prior to AF ablation, without compromising image quality.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Imaging Studies III: Computed Tomography
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Framing Effects

